Top Burette Cap with needleless valve 11C021
Top Burette Cap with needleless valve 11C021
for IV bag
Color : Blue
Material : PC + ABS
Color : Blue
Material : PC + ABS
Model :
11C021
- 11C021
- for IV bag
- Color : Blue
- Material : PC + ABS
- Resist high pressure from back side to 7kg/cm2 of air.
- In accordance with leaking test: 2kg/cm2 of air (Above ISO 8536-4-A.2)
- Metal components are not included, MRI compatibility.
- Materials - Medical grade polycarbonate and medical grade silicone, biocompatibility test pass.
- Pressure type - Negative pressure.
- Functional activation - Up to 200 actuations.
- Flow rate - 150 ml / min (at 36 inch head height)
- Residual volume - 0.3ml (inside connector only)
- Reflux Volume - 0.3ml
- Flush Volume - 1.5ml
- Disconnect force - <1kg
- Back Pressure 70psi
- Pressure Maximum 325psi
- Alcohol - Compatible : Yes.
- Lipid - Compatible : Yes.
- Needleless design:
- Eliminates the risk of needle-stick injuries for both healthcare workers and patients.
- Metal-free construction:
- Composed entirely of medical-grade plastic materials, ensuring compatibility with a wide range of infusion products.
- ISO 594 compliance:
- Adheres to ISO 594 standards for secure fitting and compatibility with standard infusion sets.
- Minimized force application:
- Designed to prevent self-dropping of the fitting part due to external force or internal pressure.
- Medical-grade materials:
- Utilizes medical-grade polycarbonate for housing and septum, ensuring biocompatibility and resistance to lipids and alcohol.
- Blood compatibility:
- Housing structure passes blood compatibility testing to minimize hemolysis during infusion.
- Durable silicone seal:
- Silicone seal withstands up to 200 actuations, ensuring long-lasting performance.
- Microbial barrier protection:
- Swabable surface around the top of the housing provides an effective barrier against microbial contamination.
- Fluorescein dye test:
- Fluorescein dye test confirms no residual dye on the swabable surface after disconnection, ensuring patient safety.
- High-pressure infusion compatibility:
- Suitable for high-pressure infusion therapy, withstanding maximum pressures of 7kg/cm2 (when not connected) and 24kg/cm2 (350PSI) when connected.
Overall, the Gen 1 Needleless Series offers a safe, reliable, and easy-to-use needleless infusion solution for a wide range of clinical applications.
- Comply with ISO 594 standards
- Simple mechanism design
- Easy to clean swabable surface.
- High pressure compatibility
- Pass biocompatibility test
- Patented model designs with multiple countries' patents.