Gen2 Needle Free Connector
Gen2 Needle Free Connector
The best choice for reducing the risk
of infection is 「Gen2」.



This Gen2 NFC patent has obtained the protection of many national invention patents in the world, including the approval of the European Union. This innovative invention solves the common blood return condition in medical clinics. If the needle-free connector mechanism does not protect the cavity, the blood will cause thrombosis when the blood is returned to the needle-free connector cavity. The medical staff has to spend time and cost to inject the anticoagulant. When the needle is pulled, the conduction tube is retracted and closed. This neutral design, because the bottom is closed, when the patient raises the arm and causes blood to return, it does not return to the cavity. If In the cavity will triggering a thrombus, so our Gen2 needle-free connector greatly reducing the risk of secondary infection. Our needle-free connector technology and patents specifically address this situation for medical staff and patients. When the needle is closed, the catheter is closed first, then the surface is sealed, the flat design is easy to disinfect, the catheter design is cylindrical and there is no corner, and the world's minimum residue The amount of 0.016ml will not cause many problems of flushing and waste of liquid medicine.
Product flushing volume measurement testThe Gen2 NFC (Needle-Free Connector) patent has secured protection through numerous national invention patents globally
Addresses the common issue of blood return in medical clinics, preventing thrombosis in the connector cavity that could occur if not properly protected.
The neutral design ensures that, when the patient raises their arm, preventing blood from returning to the cavity and significantly reducing the risk of thrombus formation
Gen2 needle-free connector design significantly reduces the risk of secondary infections associated with thrombus formation.
Our needle-free connector technology and patents are tailored to address critical situations faced by both medical staff and patients.
When the needle is closed, the catheter is closed first, followed by surface sealing, ensuring a secure and hygienic connection.
The flat design of the connector surface makes it easy to disinfect, promoting a clean and safe medical environment.
The catheter design is cylindrical with no corners, minimizing the risk of residue buildup and ensuring smooth liquid medicine flow.
With a world-leading minimal residue of 0.016ml, flushing-related problems and liquid medicine wastage are significantly reduced.
Gen2 Needle Free Connector 14C007
Color : Transparent
Material : PC + MABS
Application : for CSTD with P/N: 12C009 CML or for infusion type
Gen2 Needle Free Connector 13C001
Color : Transparent
Material : PC + MABS
Application : for infusion type
Straight type connector 18C024
Color : Yellow + Transparent
Material : PC + MABS
Gen2 Needle Free Connector 16C008
Color : Transparent
Material : PC + MABS
Application : for infusion type
Gen2 Needle Free Connector 16C002
Color : Transparent
Material : PC + MABS
Application : for infusion type
Gen2 Needle Free Connector 16C001
Color : Transparent
Material : PC + MABS
Application : for infusion type
Gen2 Needle Free Connector 16C008
Color : Transparent
Material : PC + MABS
Application : for infusion type
Gen2 Needle Free Connector 13C015
Color : Transparent
Material : PC + MABS
Application : for infusion type
Gen2 Needle Free Connector 11C024
Color : Transparent
Material : PC + MABS
Application : for infusion type
Gen2 Needle Free Connector 16C004
Color : Transparent
Material : PC + MABS
Application : for infusion type
Gen2 Needle Free Connector 16C007
Color : Transparent
Material : PC + MABS
Application : for infusion type
Gen2 Needle Free Connector 11C025
Color : Transparent
Material : PC + MABS
Application : for infusion type